Surface casing is a large-diameter, relatively low-pressure pipe string that is run after the conductor (or drive pipe) but before any intermediate casing. It is cemented in place and extends from the surface — or mudline for offshore wells — down to a predetermined depth, typically penetrating through soft, unconsolidated surface formations and into competent rock below.
API Formal Definition (API RP 90): "Casing that is run inside the conductor casing to protect shallow water zones and weaker formations. The surface wellhead is normally installed on this casing."
Surface casing is not the same as conductor pipe, which is a smaller, shallower string driven or jetted in before surface casing. Surface casing is the first string to receive a cement job, the first string capable of supporting a BOP stack, and the first string that must provide pressure containment if a shallow gas kick occurs.
Every surface casing string is designed with five non-negotiable purposes:
Surface casing must provide sufficient burst and collapse strength to support the BOP stack. The BOP — which can weigh 50-200 tons onshore and over 1,000 tons offshore — is bolted to the surface wellhead, which sits on top of the surface casing. If surface casing fails under BOP load or pressure, a blowout becomes unavoidable.
In almost every onshore well, surface casing is set through and cemented across freshwater aquifers. The cement sheath behind the casing prevents drilling fluids, produced water, and hydrocarbons from migrating into public drinking water sources — an absolute requirement under environmental regulations (EPA, OSPAR, etc.).
Surface formations are often fractured, cavernous, or highly porous. Once surface casing is set and cemented, it seals off these zones so that drilling mud can be circulated to the surface without being lost to the formation.
One of the most dangerous well control scenarios is a shallow gas kick — gas entering the wellbore from a shallow formation during deepening operations. Surface casing provides the pressure barrier required to detect, control, and safely circulate out such a kick.
Surface casing becomes the structural anchor for the rest of the well. All subsequent casing strings (intermediate, production) are run through it. In deviated wells, surface casing may also cover the build section to prevent keyseating of the formation during deeper drilling.
Field Note: Surface casing is often underrated in well design. Engineers focus heavily on production casing burst ratings but sometimes cut corners on surface casing. The Macondo blowout (Deepwater Horizon) involved a failure sequence that began with surface casing pressure integrity issues — a reminder that every string matters.
Oil wells typically use between 3 and 8 casing strings, depending on well depth, formation complexity, and pressure regimes. Here's how surface casing fits into the full picture:
| String | Order | Typical Size | Key Purpose |
|---|---|---|---|
| Conductor / Drive Pipe | 1st (first) | 18" - 36" OD | Stabilize near-surface, prevent shallow washouts. Driven or jetted, NOT always cemented. |
| Surface Casing | 2nd | 13-3/8", 16", 18-5/8", 20" OD | ⭐ BOP mount, aquifer protection, shallow gas isolation. Always cemented to surface. |
| Intermediate Casing | 3rd-5th | 9-5/8", 10-3/4", 11-7/8", 13-3/8" OD | Isolate problem formations, control pressure, enable deepening. May be cemented full-length or top-cemented. |
| Production Casing | Last (innermost) | 4-1/2", 5", 7", 9-5/8" OD | Production conduit, pressure containment for hydrocarbons. Cemented across pay zone. |
| Production Tubing | Inside production casing | 2-3/8", 2-7/8", 3-1/2", 4-1/2" OD | Removable conduit through which fluids actually flow. |
Surface casing specifications are driven primarily by hole size and formation pressure. The drill bit used to open the hole dictates the minimum casing size (plus overgage allowance), and the expected pressure at casing shoe depth dictates the required burst and collapse ratings.
| Nominal Size (OD) | Typical Weight (lb/ft) | Hole Size Range | Common Applications |
|---|---|---|---|
| 13-3/8" (339.7mm) | 48 - 72 lb/ft | 17-1/2" - 20" bit | Onshore oil & gas wells, shallower offshore platforms |
| 16" (406.4mm) | 55 - 84 lb/ft | 20" - 24" bit | Standard deepwater surface casing, high-capacity wells |
| 18-5/8" (473.1mm) | 87 - 134 lb/ft | 24" - 26" bit | Ultra-deepwater, high-pressure wells |
| 20" (508mm) | 94 - 133 lb/ft | 26" - 30" bit | Heavy-duty, high-BOP-load wells, Arctic offshore |
Surface casing is almost always plain carbon steel per API 5CT, with the most common grades being:
Connection types for surface casing are nearly always buttress thread (BT) or premium connections. The high tensile loads during running and pressure testing make round thread (STC/LTC) unsuitable for the larger sizes.
GNEE Stock Availability: We maintain 3,000+ tons of surface casing inventory in API 5CT J-55, K-55, and N-80 grades across 13-3/8", 16", and 20" nominal sizes. Custom grades (P-110, Q-125) and lengths (10m, 12m, 13.5m) available on 25-ton MOQ.
The surface casing installation is a high-risk, time-sensitive operation. Every step must be executed according to the well program, with QA/QC checks at each stage.
STEP 1 Conductor Drive & Hole Section
Conductor pipe (18"-36") is driven or jetted to refusal. A diverter system is installed on top to handle any shallow flow while drilling the surface hole section (typically 17-1/2" to 30" diameter).
The surface hole is drilled to casing point — the design depth where surface casing will be set. This depth is chosen to penetrate all fresh water aquifers and reach competent rock. Casing point is confirmed via formation evaluation (gamma ray, density logs).
Drill string is tripped out. Hole is circulated with clean drilling fluid to remove cuttings. A wiper trip may be run to ensure the hole is properly conditioned.
Casing joints are picked up, inspected (dimensional check, visual inspection, drift test), and made up with the specified connection. The casing is lowered into the hole using the traveling block. Centralizers may be installed to ensure standoff and proper cement placement.
The casing is typically pressure-tested (1.5× minimum expected pressure) before cementing. Cement slurry is pumped down through the casing and displaced up the annulus. For surface casing, cement is usually circulated back to surface or mudline (full cement job) for maximum zonal isolation.
After cement sets (typically 8-24 hours), a shoe test is performed to verify casing shoe integrity. The surface housing / wellhead assembly is bolted to the top of the surface casing string.
The blowout preventer stack — consisting of annular preventers, ram preventers (pipe, blind, shear), kill/choke lines, and control system — is installed on the surface wellhead. The BOP is then pressure-tested to validate its sealing capability.
Surface casing design, material, and testing follow these primary American Petroleum Institute (API) and ISO standards:
API Spec 5CT / ISO 11960 — Casing and Tubing. The primary standard for material grades, dimensions, weights, mechanical properties, and end connections. Specifies J-55, K-55, N-80, P-110, Q-125 grades and more.
API RP 5C3 — Bulletin on Casing, Tubing and Drill Pipe Performance Properties. Provides formulas for calculating burst pressure, collapse resistance, and axial load capacity.
API RP 90 — Annular Casing Pressure Management for Offshore Wells. Defines surface casing role in well pressure management.
API Spec 6A / ISO 10423 — Wellhead and Christmas Tree Equipment. Covers the surface wellhead that mounts on surface casing.
API RP 16Q — Qualification of Pressure Relief Valves for Well Control Equipment.
ISO 16530-1 — Petroleum and Natural Gas Industries — Transparent Data Exchange — Part 1: Wellbore geometry.
| Aspect | Onshore | Offshore |
|---|---|---|
| Set Depth | 500 - 2,000m (varies by aquifer depth) | 500 - 4,000m + (deepwater wells go very deep) |
| Cement Top | Surface (ground level) | Mudline (seafloor) |
| Casing Size | 13-3/8" — 16" typical | 16" — 20" typical (larger for high BOP weight) |
| Corrosion | Minimal (onland formation, less seawater) | Severe (seawater environment may require CRA) |
| Load | 50-200 ton BOP | 1,000+ ton BOP + riser loads |
| Aquifer Protection | Primary design driver | Still important, but shallow gas focus |
| Installation Risk | Lower (rig floor only) | Higher (subsea operations, riser margin pressure) |
The overwhelming majority of surface casing uses plain carbon steel per API 5CT. However, three special cases warrant upgraded materials:
Case 1 — Sour Service (H₂S): When surface formations contain hydrogen sulfide, standard carbon steel may suffer sulfide stress cracking (SSC). Specify API 5CT grades with SSC testing (e.g., N-80 Q, P-110 Q) or upgrade to 13% Cr or duplex stainless steel for severe environments.
Case 2 — High CO₂: Carbon dioxide corrosion in surface casing annuli can be severe, especially offshore where water displaces drilling fluid. Consider CRA-lined carbon steel or monel/duplex premium strings.
Case 3 — Arctic / Permafrost: Low temperatures may require grades with improved toughness (CT testing at -20°C or lower) to prevent brittle fracture during BOP installation or cementing operations.
Surface casing set depth varies by well location and local regulations. Onshore: typically 500-2,000 meters, depending on freshwater aquifer depth and surface formation competence. Offshore: 500-4,000+ meters. The governing principle is that surface casing must penetrate all shallow water-bearing formations and cement solidly into competent rock below.
Full-length cementing ensures maximum zonal isolation of freshwater aquifers and shallow gas zones, prevents fluid migration along the annulus, and provides maximum structural support for BOP installation. This is a unique requirement of surface casing — intermediate and production casing may be top-cemented or partially cemented.
Conductor pipe is the shallowest, largest-diameter pipe (18"-36") run first. It's driven or jetted and may not be cemented. Its purpose is simply to stabilize the near-surface hole. Surface casing (13-3/8"-20") is run inside the conductor, drilled deeper, always cemented, and is the first string that can support a BOP stack.
No. Surface casing is cemented in place for the life of the well. Once set and cemented, it cannot be retrieved. Production tubing inside production casing is the only retrievable tubular string.
Minimum burst rating = 1.5× the maximum expected surface pressure during drilling. Minimum collapse rating must exceed the maximum expected external pressure (formation + mud weight). Additionally, surface casing must withstand the full weight of the BOP stack plus drill string axial loads.
The casing shoe is the bottom joint of surface casing, which has a float collar and guide shoe assembly that facilitates cementing. After cement sets, a shoe test (leak-off test) is performed to verify the cement sheath and casing shoe can hold pressure — failure here is a major well control risk.
N-80 is the industry workhorse — it offers excellent strength at moderate cost. Use K-55 for shallower, low-pressure onshore wells to save cost. Use P-110 or Q-125 for deeper surface runs or high-pressure environments. Upgrade to SSC-resistant grades if H₂S is present, and CRA-lined carbon steel for severe CO₂ corrosion.
Yes. GNEE maintains 3,000+ tons of surface casing inventory in API 5CT J-55, K-55, and N-80 grades across 13-3/8" (339.7mm), 16" (406.4mm), and 20" (508mm) nominal sizes with 48-133 lb/ft wall thicknesses. P-110 and Q-125 custom grades, SSC-certified materials, and CRA options are available on request. Reply within 24 hours.